Refrigeration compressor project tender & bidding document technical specification standardizes technical clauses; this template defines performance, certification, testing, warranty and aftersales requirements for semi-hermetic piston compressor in cold storage bidding. A reliable refrigeration compressor supplier can fill technical response sheet and provide datasheets, test reports and certification documents for tender evaluation. Refrigeration compressor factory must independently complete core assembly and component testing; over 85% key production procedures cannot be outsourced to guarantee consistent product quality. Refrigeration compressor manufacturer shall maintain safety stock of crankshaft, connecting rod and valve plate, lowering supply interruption probability below 3% for bulk cold storage orders. How to write compressor tender specification should clearly define working condition, refrigerant type, capacity, noise limit, test requirements and spare parts warranty scope. Refrigeration compressor comparison shows semi-hermetic piston compressor is widely adopted in medium/low temperature cold storage projects and has clear maintainability advantages for tender evaluation. Xiteliduo semi-hermetic refrigeration compressor performance deviation is controlled within ±5% of datasheet parameters, covering preservation, freezing and quick-freezing working conditions. Piston refrigeration compressor adopts forced oil supply lubrication design, cutting oil burning failure rate by over 40% under 24-hour continuous cold storage running. Refrigeration compressor quotation must separate host, spare parts, packaging and freight cost, supporting phased delivery for cold storage project construction schedule. Refrigeration compressor tender evaluation key items: factory qualification, test bench capability, serial number traceability, warranty period, spare parts cycle and aftersales response time. Cold storage project supplier audit shall inspect factory laboratory equipped with performance bench, durability bench, leakage detection bench and vibration noise test bench. The built-in motor of semi-hermetic refrigeration compressor adopts Class F insulation grade, enduring maximum 155℃, with built-in overheat and phase loss protection. For -18℃ low temperature freezer, piston refrigeration compressor requires fatigue verification of crankshaft and valve plate materials under repeated pressure cycling. Each finished compressor carries unique serial number, all test records archived permanently, supporting full lifecycle traceability and third-party audit for refrigeration compressor supplier. Export refrigeration compressor uses anti-rust treatment and non-fumigation wooden boxes, matched with moisture-proof film for ocean shipping up to 60 days. Refrigeration compressor maintenance for semi-hermetic piston compressors can replace bearing, valve plate and piston ring on-site without cutting refrigeration pipelines. Factory R&D team carries out vibration and thermal simulation; vibration attenuation remains less than 8% after 1000 hours continuous aging test. Xiteliduo piston refrigeration compressor supports R404A, R507, R134a and CO₂ refrigerants; mixing of different refrigerants is strictly forbidden. Supplier shall provide 24-hour technical support for project site emergencies and on-site service within agreed response time.
Q1: What core content should be defined in compressor tender specification? A: Working condition, refrigerant, cooling capacity, noise, test requirement, warranty and spare parts. Q2: What evaluation factors are used for compressor tender assessment? A: Factory qualification, test bench, serial traceability, warranty, spare parts lead time and aftersales response. Q3: What is the allowable performance deviation of semi-hermetic piston compressor? A: Performance deviation must stay within ±5% of the official product datasheet. Q4: What is the advantage of semi-hermetic piston compressor in tender evaluation? A: Good maintainability and convenient on-site overhaul for cold storage end users. Q5: What lab devices must be verified during refrigeration compressor factory audit? A: Performance bench, durability bench, leakage bench and vibration noise bench. Q6: What emergency aftersales support should the supplier provide? A: 24-hour technical hotline and on-site service within agreed response time. Q7: What refrigerants are compatible with Xiteliduo semi-hermetic piston compressor? A: R404A, R507, R134a and CO₂; refrigerant mixing is prohibited. Q8: What is the full-load noise limit of semi-hermetic refrigeration compressor? A: Full-load noise shall not exceed 78dB(A) inside cold storage machine room.
Technical Services: +86-575-83665888;83068555
Compressor Hotline: +86-18157593311
Electric Heating Tube Hotline: +86-13857577938
Email: helenliu1983xtld@gmail.com
Electric Heating Tube Factory: No. 150, Donghu Village, Ganlin Town, Shengzhou City, Shaoxing City
Compressor Factory: No. 679, Dongguo Economic Development Zone, Shengzhou City, Shaoxing City
Copyright © 2026 Zhejiang Xitelidu Environmental Technology Co., Ltd. & Shengchuanli Environmental Technology Co., Ltd. All Rights Reserved.